All equipment

Equipment 05

Pulsed Nuclear Magnetic Resonance Spectrometer

Modern pulsed nuclear magnetic resonance spectrometer AVANCE AV300, manufactured by BRUKER BIOSPIN (Germany), in a solid-state modification, providing broad capabilities of Nuclear Magnetic Resonance - the study of solids using the latest techniques

MODEL, MANUFACURERAvance AV-300 “Bruker” (Germany)
DirectorySINTERLAB · EQ-05
Pulsed Nuclear Magnetic Resonance Spectrometer
LAB EQUIPMENT05

Purpose

The main purpose of the device is a modern pulsed nuclear magnetic resonance spectrometer AVANCE AV300, manufactured by BRUKER BIOSPIN (Germany), in a solid-state modification, providing extensive capabilities for Nuclear Magnetic Resonance - the study of solids using the latest techniques. Areas of application: Measurement of NMR spectra of solid-state samples for various nuclei in the temperature range of 120-6000 K, in order to study the structure, phase transitions, internal mobility. Precision measurements of the orientation dependences of NMR spectra in single crystals using a special sensor with a goniometer. Measurements of high-resolution spectra in powdered samples, using the technique of rotating the sample at a magic angle. Main technical characteristics Magnetic field 7.049 T Larmor frequency of protons 300 MHz Transmitter power 300 MHz - 1 kW 14-122 MHz - 1 kW Duration of 90° pulse About 2 μs Rotor frequency MAS 15 kHz Description of the theoretical foundations and effects on which the operation of the device is based Zeeman effect. A. Abraham “Nuclear Magnetism”, IL publishing house 1963 R. Ernst, J. Bodenhausen, A. Vokaun “NMR in one and two dimensions” Mir publishing house, 1990 Substances under study Solid substance - diamagnetic and paramagnetic crystals and powders. Required volume 0.01-1 cm3 depending on the working core and sensor Possibility of change external conditions indicating the range Constant magnetic field 7 T, sample temperature can vary from 150 K to 450 K (some sensors operate in a more limited temperature range, magic angle rotation sensor only at 300 K) Time: maximum time for establishing the operating mode, hour the device is ready for operation constantly time of continuous operation, hour time unlimited characteristic time for one measurement Duration of recording spectra varies greatly depending on the working core, relaxation characteristics of the sample, methods used registration (from several minutes to tens of hours) order execution time depends on the contents of the order how long the device works on a contract basis (third party organizations) not defined units. measurements: number of samples Number of consumables: name of materials, units. measurements Cryostat: liquid nitrogen 2400 l/year, liquid helium 120 l/year, temperature control system up to 10 l/hour liquid nitrogen Cost of measurement Data formats produced by the device A set of files available for reading and processing only on AVANCE spectrometers Programs for converting and processing the received data Licensed programs, programs developed at the Institute of Physics Methods of obtaining information for the customer: flash memory, floppy disk, CD, e-mail, hard copy, etc. Hard copy of NMR spectra, text files of spectra and processing results on any storage media

Technical Description

Parameters and application.

The main purpose of the device is a modern pulsed nuclear magnetic resonance spectrometer AVANCE AV300, manufactured by BRUKER BIOSPIN (Germany), in a solid-state modification, providing extensive capabilities for Nuclear Magnetic Resonance – the study of solids using the latest techniques.

Areas of application: Measurement of NMR spectra of solid-state samples for various nuclei in the temperature range of 120-6000 K, in order to study the structure, phase transitions, internal mobility. Precision measurements of the orientation dependences of NMR spectra in single crystals using a special sensor with a goniometer. Measurements of high-resolution spectra in powdered samples, using the technique of rotating the sample at a magic angle. Main technical characteristics Magnetic field 7.049 T Larmor frequency of protons 300 MHz Transmitter power 300 MHz – 1 kW 14-122 MHz – 1 kW Duration of 90° pulse About 2 μs Rotor frequency MAS 15 kHz Description of the theoretical foundations and effects on which the operation of the device is based Zeeman effect. A. Abraham “Nuclear Magnetism”, IL publishing house 1963 R. Ernst, J. Bodenhausen, A. Vokaun “NMR in one and two dimensions” Mir publishing house, 1990 Substances under study Solid substance – diamagnetic and paramagnetic crystals and powders. Required volume 0.01-1 cm3 depending on the working core and sensor Possibility of change external conditions indicating the range Constant magnetic field 7 T, sample temperature can vary from 150 K to 450 K (some sensors operate in a more limited temperature range, magic angle rotation sensor only at 300 K) Time: maximum time for establishing the operating mode, hour the device is ready for operation constantly time of continuous operation, hour time unlimited characteristic time for one measurement Duration of recording spectra varies greatly depending on the working core, relaxation characteristics of the sample, methods used registration (from several minutes to tens of hours) order execution time depends on the contents of the order how long the device works on a contract basis (third party organizations) not defined units. measurements: number of samples Number of consumables: name of materials, units. measurements Cryostat: liquid nitrogen 2400 l/year, liquid helium 120 l/year, temperature control system up to 10 l/hour liquid nitrogen Cost of measurement Data formats produced by the device A set of files available for reading and processing only on AVANCE spectrometers Programs for converting and processing the received data Licensed programs, programs developed at the Institute of Physics Methods of obtaining information for the customer: flash memory, floppy disk, CD, e-mail, hard copy, etc. Hard copy of NMR spectra, text files of spectra and processing results on any storage media